Digital PCR & Molecular Monitoring · Knowledge Centre

BCR::ABL1 Molecular Monitoring in CML: Understanding the International Scale, Molecular Response and Digital PCR

Molecular monitoring is an important component of the laboratory assessment of chronic myeloid leukemia (CML). The sequential measurement of BCR::ABL1 transcripts allows the depth of molecular response to be followed over time, supporting clinical monitoring and the early laboratory detection of rising disease levels.

Professional Education Updated: 6 October 2026

At a Glance

BCR::ABL1 molecular monitoring evaluates transcript levels over time.

RT-qPCR remains the most commonly used molecular monitoring method.

RT-dPCR is now recognized as an alternative molecular monitoring approach.

Standard BCR::ABL1 results are reported using the International Scale where applicable.

Molecular-response categories correspond to defined BCR::ABL1 IS levels.

Deep molecular response requires adequate analytical sensitivity.

“Not detected” does not automatically mean zero residual disease.

Absolute dPCR quantification does not automatically equal International Scale reporting.

What Is BCR::ABL1 Molecular Monitoring?

But a routine monitoring result is more than a single number. Between the analytical measurement and the clinical report sits a chain of standardization decisions: which transcript types the assay covers, which reference gene is measured alongside BCR::ABL1, how the result is aligned to the International Scale (IS), and what level of molecular response the complete workflow can reliably support.

This article therefore focuses on a central laboratory question:

How does a laboratory convert an analytical BCR::ABL1 measurement into a standardized result that can be interpreted within an internationally recognized molecular-response framework?

Understanding this conversion — and its limits — matters for any laboratory implementing or evaluating BCR::ABL1 molecular monitoring, regardless of the measurement technology it uses.

Molecular monitoring is the longitudinal measurement of BCR::ABL1 transcript levels. Rather than a single qualitative detection result, monitoring measures how BCR::ABL1 levels change across sequential specimens, most commonly peripheral blood.

The value lies not simply in detecting BCR::ABL1, but in measuring change over time within an appropriate standardized framework. A single result provides information at one time point; the trend across standardized sequential measurements is what gives molecular monitoring its clinical meaning.

Conceptually, the monitoring pathway runs:

  1. 1BCR::ABL1-positive CML
  2. 2BCR::ABL1 transcript measurement
  3. 3Reference-gene relationship
  4. 4International Scale
  5. 5Molecular response
  6. 6Longitudinal monitoring

From Measurement to Standardization

Measurement to standardization

  1. 1Local analytical measurement
  2. 2BCR::ABL1 + reference-gene measurement
  3. 3Validated calibration / traceability
  4. 4BCR::ABL1 International Scale
  5. 5Molecular response
  6. 6Longitudinal interpretation

A BCR::ABL1 measurement becomes clinically comparable through validated standardization and reporting — not through quantification alone.

What Does BCR::ABL1IS Mean?

BCR::ABL1IS means a BCR::ABL1 result expressed on the International Scale. For patients expressing the standard major transcripts (e13a2 and/or e14a2), results are typically expressed as a ratio of BCR::ABL1 to an appropriate reference gene, aligned to the International Scale.

Appropriate reference genes include ABL1, BCR and GUSB, depending on the validated methodology. Current European LeukemiaNet laboratory guidance notes that any of these three is acceptable for routine analysis, that ABL1 is used in the great majority of testing laboratories, and that other reference genes are not recommended because they have not been calibrated to the International Scale. Laboratories do not all use the same reference gene, and the reference gene is part of the validated method, not an interchangeable detail.

Why does the International Scale exist? Historically, differences in assay design, reference genes, calibration and reporting methods could produce meaningful variation between laboratories measuring the same patient material. The International Scale provides a harmonized framework anchored to a standardized baseline, so that molecular-response categories have consistent meaning across laboratories, methods and time.

Understanding Molecular Response

Molecular response is described using a logarithmic framework relative to the standardized baseline. The currently accepted approximate International Scale relationships are:

Molecular response categories — BCR::ABL1 IS levels and approximate log reductions
CategoryBCR::ABL1 IS levelApproximate log reduction
MR2≤ 1%2-log
MMR / MR3≤ 0.1%3-log
MR4≤ 0.01%4-log
MR4.5≤ 0.0032%4.5-log
MR5≤ 0.001%5-log

MMR means Major Molecular Response. MR4 and deeper are generally considered deep molecular response (DMR) territory.

Two cautions belong alongside this table. First, molecular-response levels are not a simple linear clinical “score” — a deeper numerical category is not automatically clinically superior, and reaching a deeper category does not by itself determine treatment decisions. Second, classifying a sample to a deep response level is only valid when the assay’s analytical sensitivity and the sample’s evaluable material support that depth of measurement, as discussed below.

The BCR::ABL1 Molecular Response Scale

100%

Standardized baseline concept

1%

MR2

0.1%

MMR / MR3

0.01%

MR4

0.0032%

MR4.5

0.001%

MR5

Reporting a deep molecular-response level requires sufficient analytical sensitivity and adequate reference-gene measurement for the individual sample.

Does Undetectable BCR::ABL1 Mean Zero Disease?

No.

A result in which BCR::ABL1 is not detected means that BCR::ABL1 was not detected within the analytical sensitivity achieved for that specimen and assay. It does not prove that no BCR::ABL1-positive cells exist anywhere in the patient.

For this reason, laboratory terminology matters. Phrases such as “complete molecular response” can imply an absolute absence of disease that molecular testing cannot establish. Current guidance favors more precise language for results below detection.

Similarly, reporting “0% BCR::ABL1 IS” is not automatically meaningful without analytical context. What carries meaning is the detection limit achieved for that specific measurement, which depends on the assay’s sensitivity and on the amount and quality of evaluable material in the sample.

Why Reference-Gene Measurement Matters

Deep molecular-response interpretation requires evidence that the sample contained sufficient evaluable material. This is where the reference gene earns its name: the reference-gene measurement quantifies the evaluable material in the same cDNA volume used to test for BCR::ABL1, and thereby establishes the sensitivity achieved for that sample.

BCR::ABL1 not detected

Adequate reference-gene measurement

May support interpretation at the achieved deep molecular-response level

BCR::ABL1 not detected

Insufficient reference-gene measurement

Cannot automatically be classified as a very deep molecular response

Current European LeukemiaNet laboratory guidance defines this explicitly. To score deep molecular response, the guidance specifies minimum sums of reference-gene transcripts measured in the same volume of cDNA — approximately 10,000 ABL1 transcripts for MR4, 32,000 for MR4.5 and 100,000 for MR5 (with correspondingly higher GUSB requirements). As a practical illustration, the guidance notes that undetected BCR::ABL1 with around 45,000 ABL1 transcripts indicates MR4.5 for that sample, whereas undetected BCR::ABL1 with fewer than 10,000 ABL1 transcripts is not evaluable for deep molecular response and should be treated as a technical failure.

The principle is simple: an undetected result is only as deep as the reference-gene measurement that supports it.

RT-qPCR in BCR::ABL1 Monitoring

RT-qPCR remains the most commonly used method for routine BCR::ABL1 molecular monitoring. Its strengths are well established:

  • established clinical use over many years of CML management;
  • extensive standardization experience, including International Scale alignment;
  • quantitative longitudinal measurement across a wide disease range;
  • International Scale reporting through validated approaches (laboratory-specific conversion factors, calibrated reference materials or validated systems);
  • mature laboratory workflows and broad availability.

None of this makes RT-qPCR obsolete, and none of it is a limitation. Standard-curve-based calibration is not a weakness when appropriately validated — as discussed in our article on digital PCR versus qPCR, qPCR can provide absolute quantification when appropriate calibration strategies are used. In BCR::ABL1 monitoring specifically, the clinical question is not whether a method uses a standard curve, but whether the complete measurement pathway is validated and traceable.

Where Does Digital PCR Fit?

Reverse transcription digital PCR (RT-dPCR), including droplet digital PCR (RT-ddPCR), measures BCR::ABL1 through a different analytical route.

The concept is straightforward: the reaction is divided into a large number of partitions. Following amplification and endpoint classification of each partition, the target concentration is estimated statistically from the positive and negative partition outcomes. This can enable absolute quantification without reliance on a conventional external calibration curve for the core concentration estimate.

Current European LeukemiaNet laboratory guidance recognizes RT-dPCR as an acceptable alternative to RT-qPCR for molecular monitoring, noting that it may offer technical advantages in some circumstances, particularly for the assessment of very low levels of disease.

Potential advantages may include:

  • partition-based quantification;
  • performance at very low target levels;
  • reduced dependence on conventional calibration curves for the analytical concentration estimate;
  • potential utility in deep molecular-response measurement.

But this must be stated just as clearly: digital PCR is not automatically superior to RT-qPCR. Clinical implementation still requires appropriate validation, quality control, transcript coverage, a reference-gene strategy and International Scale alignment where IS reporting is intended. A dPCR concentration is an analytical result, not a clinical classification.

BCR::ABL1 molecular monitoring
RT-qPCR — quantitative measurement RT-dPCR — partition-based quantification
Validated standardization BCR::ABL1 IS → molecular response

Both RT-qPCR and RT-dPCR results reach clinical reporting through the same requirement: validated International Scale standardization. Neither route is inherently “better”.

If dPCR Is Absolute, Why Is the International Scale Still Required?

Absolute quantification and clinical standardization answer different questions.

Absolute quantification addresses: “How much target was measured by this analytical system?”

International Scale standardization addresses: “How does the BCR::ABL1 result relate to the internationally harmonized molecular-response framework?”

Absolute quantification

Analytical question: “How much target was measured?”

Focus: Measurement within the analytical system

International Scale

Standardization question: “How does this result relate to the harmonized BCR::ABL1 molecular-response framework?”

Focus: Comparable clinical reporting

Absolute quantification

“How much target was measured by this analytical system?”

International Scale standardization

“How does the result relate to the harmonized molecular-response framework?”

Absolute quantification ≠ automatic International Scale reporting.

Therefore:

Absolute quantification ≠ International Scale standardization, and dPCR ≠ automatic BCR::ABL1 IS.

A dPCR assay may provide an absolute estimate of BCR::ABL1 transcript concentration in the analyzed material. That number still has to be related to the reference gene, aligned to the International Scale and validated as part of the monitoring pathway before it can be reported as a molecular-response level. Per current ELN laboratory guidance, IS conversion applies equally to results from RT-qPCR and RT-dPCR: laboratories either derive the IS by applying a laboratory-specific conversion factor to the raw BCR::ABL1/reference-gene ratio, or use a validated kit or system that reports directly on the IS.

How alignment is achieved may involve validated conversion factors, calibrated reference materials or appropriately validated standardized systems, depending on the methodology. No single calibration approach is universally required — but some validated route to the IS is required, whatever the measurement technology.

Why Standardization Matters

International reference materials and standardized reporting were developed because inter-laboratory variation had real consequences. Historically relevant sources of variation included:

  • assay design;
  • reference-gene choice and measurement;
  • calibration approach;
  • analytical workflow;
  • reporting methods.

The first World Health Organization International Genetic Reference Panel for the quantitation of BCR::ABL1 mRNA (NIBSC 09/138) provides a higher-order reference for calibration. Together with secondary reference materials, validated conversion procedures and appropriately calibrated systems, this supports traceability and harmonization of BCR::ABL1 measurement.

This should not be oversimplified. WHO reference materials do not make every assay identical. What reference materials and validated calibration strategies do is help laboratories align their measurements to a common reporting framework, so that a BCR::ABL1 IS value carries consistent meaning regardless of where or how the underlying measurement was performed.

Standard and Atypical BCR::ABL1 Transcripts

Most CML patients express the standard major BCR::ABL1 transcript types, commonly described as e13a2 and/or e14a2. Current ELN laboratory guidance indicates that these account for the great majority of CML cases — approximately 98% — with e14a2 the more common of the two.

Atypical BCR::ABL1 transcripts can require different molecular-monitoring approaches. An assay designed for standard transcript types will not automatically detect or quantify atypical fusions, and a patient with an atypical transcript should not automatically be monitored using such an assay. Current guidance recommends that patients expressing atypical fusions are monitored using bespoke validated assays, with results expressed as individual molecular responses relative to baseline — rather than on the International Scale, which is calibrated for the standard transcripts.

At the implementation level, this means transcript coverage is a first-order design decision for a monitoring service, not a footnote.

What Should a Laboratory Consider When Implementing BCR::ABL1 Monitoring?

1

Intended clinical use

What molecular-monitoring service is being implemented, and for which clinical pathway?

2

Transcript coverage

Which BCR::ABL1 transcript types are detected and quantified?

3

Sample type and pre-analytical workflow

How are samples collected, transported, processed and stabilized?

4

RNA extraction and reverse transcription

How are RNA quality and cDNA generation controlled?

5

Reference-gene strategy

Which validated reference gene is used, and how is evaluable material assessed?

6

Quantification methodology

RT-qPCR, RT-dPCR or another validated approach?

7

Analytical sensitivity

What level of molecular response can the complete workflow reliably support?

8

International Scale traceability

How are results aligned to BCR::ABL1 IS, and how is that alignment validated?

9

Quality control and external quality assessment

How is ongoing performance monitored over time?

10

Reporting

How are BCR::ABL1 IS values and molecular-response categories communicated, including not-detected results with their achieved sensitivity?

11

Longitudinal comparability

Can sequential results be meaningfully compared across time?

12

Training and technical support

Can the workflow be implemented and maintained reliably by the laboratory team?

  1. Transcript coverage

  2. Sample & RNA workflow

  3. Reverse transcription

  4. Reference gene

  5. qPCR / dPCR measurement

  6. Analytical sensitivity

  7. IS traceability

  8. Quality control

  9. Reporting

  10. Longitudinal monitoring

BCR::ABL1 molecular monitoring is a complete measurement and standardization workflow, not simply a PCR instrument selection.

Molecular Monitoring Is Longitudinal

One of the fundamental purposes of BCR::ABL1 monitoring is following molecular response over time. A single result provides information at one time point. Sequential standardized measurements provide the longitudinal context in which trends, stability and change become visible.

This is also why standardization and longitudinal comparability are inseparable: only results produced within a consistently validated measurement framework can be meaningfully compared across months and years.

Accurate measurement of molecular response supports clinical monitoring, and reliable deep molecular-response assessment can be clinically important. How molecular results inform treatment decisions — including any change or discontinuation of therapy — sits with the treating clinical team and applicable clinical guidance, outside the scope of this laboratory article.

Accuflex DX Solutions

BCR::ABL1 Molecular Monitoring Support from Accuflex DX

Implementing BCR::ABL1 molecular monitoring requires more than selecting a PCR platform.

Laboratories need to consider transcript coverage, sample and RNA workflow, reverse transcription, reference-gene strategy, analytical sensitivity, International Scale traceability, quality control, reporting and validation of the complete measurement process.

Accuflex DX supports laboratories in evaluating molecular workflows from analytical technology through implementation, training and ongoing technical support.

Key Takeaway

BCR::ABL1 molecular monitoring depends on more than detecting or quantifying a molecular target.

A clinically useful monitoring pathway connects:

BCR::ABL1 transcript measurement → adequate reference-gene measurement → analytical sensitivity → validated International Scale standardization → molecular-response reporting → longitudinal monitoring

RT-qPCR and RT-dPCR can both contribute to BCR::ABL1 molecular monitoring when implemented within an appropriately validated workflow.

The key principle is: Absolute quantification ≠ International Scale standardization.

References

  1. Apperley JF, Milojkovic D, Cross NCP, Hjorth-Hansen H, Hochhaus A, Kantarjian H, et al. 2025 European LeukemiaNet recommendations for the management of chronic myeloid leukemia. Leukemia. 2025;39(8):1797–1813. Available from Leukemia (Nature) →
  2. Cross NCP, Ernst T, Branford S, Cayuela J-M, Deininger M, Fabarius A, et al. European LeukemiaNet laboratory recommendations for the diagnosis and management of chronic myeloid leukemia. Leukemia. 2023;37(11):2150–2167. Available from PubMed Central →
  3. White HE, Matejtschuk P, Rigsby P, Gabert J, Lin F, Wang YL, et al. Establishment of the first World Health Organization International Genetic Reference Panel for quantitation of BCR-ABL mRNA. Blood. 2010;116(22):e111–e117. Available from PubMed →
  4. Scott S, Cartwright A, Francis S, Whitby L, Sanzone AP, Mulder A, et al. Assessment of droplet digital polymerase chain reaction for measuring BCR-ABL1 in chronic myeloid leukaemia in an international interlaboratory study. British Journal of Haematology. 2021;194(1):53–60. Available from PubMed →
  5. Furuya D, Moriai M, Koizumi Y, Endo T, Asanuma K, Yanagihara N, Takahashi S. Analysis of major BCR-ABL1 mRNA by digital polymerase chain reaction is useful for prediction of international scale. International Journal of Clinical Oncology. 2019;24(7):871–875. Available from PubMed →

This article is intended for professional educational purposes and does not replace product instructions for use, assay validation, laboratory quality procedures, applicable clinical guidelines or professional judgement.